Archive for the '3270' Category

Programmed Mouse Buttons Ignored by TN3270 and TN5250

Friday, April 20th, 2007

It is possible to program the mouse buttons in TinyTERM 4.x. However, the programming is ignored by the TN3270 and TN5250 emulations. This feature was added to those emulations in TinyTERM 4.30.

CR 380

Page Setup for TN3270 and TN5250

Friday, April 20th, 2007

Options set in TinyTERM Plus’ Printer Setup and Page Setup dialogs are ignored by TN3270 and TN5250 emulations. They always use the system defaults instead for print screens. This was fixed in TinyTERM 4.30.

CR 315

SNA Connections

Monday, April 16th, 2007

The SNA protocol is a native IBM network protocol. TinyTERM does not support it for TN3270 or TN5250 emulations. Only TCP/IP connections are supported.

TN3232 Caused an Invalid Page Fault

Tuesday, April 10th, 2007

The full error message is, “This program has performed an illegal operation and will be shut down. TN3232 caused an invalid page fault in Winfws32.dll.” To get rid of this error, uncheck the “Enable Extended Attributes” setting in the Attributes tab of the Preferences.

TinyTERM 4.04, TN3270 and Firewall

Thursday, April 5th, 2007

Using TinyTERM Plus Edition 4.04, how do you connect through a telnet firewall to an IBM host with TN5250 or TN3270 terminal emulation?

Configure a sessions using the TTY terminal type and a telnet connection to connect to the firewall as follows:

  • Connection host: firewall name or IP address
  • Connection Type: telnet
  • Terminal Emulation: TTY
  • Telnet Terminal Type: (depends on IBM emulation required)
    • 3270
      • IBM-3278-2
      • IBM-3278-3
      • IBM-3278-4
      • IBM-3278-5
    • 5250
      • IBM-3179-2
      • IBM3477-FC
  • Save the session.
  • Telnet to the firewall using this configuration. When the firewall prompts for the host, enter the hostname or IP address of the destination host.
  • Depending on your firewall, you may have to hit the Enter key once to display the initial host screen.

NOTE 1: TinyTERM senses telnet binary mode to know when to switch emulations from TTY to one of the IBM emulations. The IBM terminal emulation desired is specified by the Telnet Terminal Type configuration.

NOTE 2: To preserve the initial firewall connection configuration do not save the session after the IBM host connection is made. TinyTERM changes your session properties when the IBM connection is made.

TN3270 Cursor Disappears

Wednesday, March 28th, 2007

In TinyTERM Plus 4.20, the cursor will sometimes disappear when using TN3270 emulation. There is no patch.

CR 301, fixed in TinyTERM Plus 4.21

100% CPU Utilization

Tuesday, March 13th, 2007

TinyTERM Plus version 4.05 will use 100% of the CPU if a session is configured for TN3270 or TN5250 emulation. TinyTERM Plus 4.10 will do the same thing with two or more sessions open using those emulations.

TinyTERM 3.3 will sometimes use 100% of the CPU regardless of the emulation chosen. Older versions of TERM or TinyTERM for Windows will do the same thing. TinyTERM does not need to be connected for this to happen.

There is no workaround for these situations. TinyTERM must be upgraded to improve its CPU utilization.

TinyTERM Plus Edition 4.05 may use 100% of the CPU after install on Windows NT 4.0, even when the TinyTERM Emulator is not running. That’s caused by the NFS client included with TinyTERM Plus Edition. To fix that, uninstall TinyTERM and NetUtils. Reboot the PC, then reinstall without the NFS component.

TinyTERM 4.31 and higher will use 100% of the CPU on Windows 98 or Me when connected via TCP/IP or modem. This does not happen on Windows 98 Second Edition, nor does it happen with serial connections.

CR 72, improved in TinyTERM 4.12
CR 294, reported in TinyTERM 4.20
CR 647, Windows 98 and Me

HLLAPI Support

Tuesday, March 13th, 2007

The TN3270 emulation type includes the HLLAPI programming interface. This was added to TinyTERM Plus in version 4.30 in the TN3232.exe program found in C:\Program Files\Century\TinyTERM\HLLAPI, rather than the default TinyTERM emulator.

TN3232.exe is no longer included in TinyTERM versions 4.60 and higher. For these versions, use the Whlapi32.dll for the HLLAPI interface.