Data Capture Opens Page Setup

TinyTERM version 4.x will sometimes bring up the Page Setup dialog when a data capture is started. If you OK the dialog, the capture goes to the printer instead of the specified file. If you Cancel the dialog, nothing is captured.

This is a bug in TinyTERM. It most often happens if you’re using a .tpx file that was opened after you started TinyTERM.

The only workaround is to exit TinyTERM, then double-click the .tpx file you want to use. While it is the only file open, try the data capture again. You may need to do this more than once. Changing the version of TinyTERM you have installed may also help.

CR 81, improved in TinyTERM 4.11
CR 501, fixed in TinyTERM 4.7.0